Search results for "Myopic astigmatism"

showing 4 items of 4 documents

Iris-fixated toric phakic intraocular lens for myopic astigmatism

2011

Purpose To evaluate the efficacy, predictability, safety, stability, and complications of the Artiflex toric iris-fixated phakic intraocular lens (pIOL) for myopic astigmatism. Setting Private practice surgery centers, Valencia and Terrassa, Spain. Design Cohort study. Methods At 12 months, refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuities, complications, pIOL misalignment, and endothelial cell count (ECC) were evaluated. Indices of success and misalignment were calculated using vector analysis. Results The study enrolled 42 eyes in 25 patients aged 21 to 39 years. The mean spherical equivalent decreased from −8.85 diopters (D) ± 2.71 (SD) to −0.37 ± 0.46 D, with …

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyVisual acuitygenetic structuresVisual AcuityIrisAstigmatismRefraction OcularPhakic intraocular lensCohort StudiesMyopic astigmatismYoung AdultPostoperative ComplicationsLens Implantation IntraocularOphthalmologyMyopiamedicineHumansIris (anatomy)Dioptremedicine.diagnostic_testbusiness.industrySuture TechniquesAstigmatismCorneal TopographyCorneal topographymedicine.diseaseeye diseasesSensory SystemsOphthalmologyTreatment Outcomemedicine.anatomical_structurePrivate practiceFemaleSurgerymedicine.symptombusinessFollow-Up StudiesJournal of Cataract and Refractive Surgery
researchProduct

Behaviour of the phakic iris-claw intraocular lens (Artisan /Verisyse) during accommodation: an optical coherence biometry study.

2007

Purpose To evaluate variations in the position of the phakic iris claw lens (Artisan®, Verisyse®) and the natural crystalline lens during the accommodation process. Methods We measured changes in position of the iris claw lens and the crystalline lens during the accommodation using optical coherence biometry (AC Master®/Carl Zeiss Meditec, Germany) in 17 patients (28 eyes) with a phakic iris claw lens implanted for high myopia and/or myopic astigmatism. Accommodative effort was obtained using an internal optical target within the measuring device. Results There was a forward shift of the phakic iris claw lens with a mean of 70 μm (8–178 μm) of the optical path length (OPL). At the same time…

Adultmedicine.medical_specialtyPhakic Intraocular LensesMaterials scienceBiometrymedicine.medical_treatmentIrisIntraocular lensRefraction OcularMyopic astigmatism03 medical and health sciences0302 clinical medicineOpticsLens Implantation IntraocularAnterior Eye SegmentOphthalmologyLens CrystallinemedicineMyopiaHumansIris clawOptical path lengthbusiness.industryHigh myopiaAccommodation OcularAstigmatismGeneral MedicineMiddle AgedOphthalmologymedicine.anatomical_structureLens (anatomy)030221 ophthalmology & optometrybusinessAccommodation030217 neurology & neurosurgeryTomography Optical CoherenceCoherence (physics)Follow-Up StudiesEuropean journal of ophthalmology
researchProduct

Predictability of intraocular lens power calculation after small-incision lenticule extraction for myopia

2019

PURPOSE To evaluate and compare the predictability of intraocular lens (IOL) power calculation after small-incision lenticule extraction (SMILE) for myopia and myopic astigmatism. SETTING Department of Ophthalmology, Philipps University of Marburg, Marburg, Germany. DESIGN Retrospective comparative case series. METHODS Preoperative evaluation included optical biometry using IOLMaster 500 and corneal tomography using Pentacam HR. The corneal tomography measurements were repeated at 3 months postoperatively. The change of spherical equivalent due to SMILE was calculated by the manifest refraction at corneal plane (SMILE-Dif). A theoretical model, involving the virtual implantation of the same…

Optics and PhotonicsRefractive errormedicine.medical_specialtyBiometrymedicine.medical_treatmentIntraocular lensRefraction OcularMyopic astigmatism03 medical and health sciences0302 clinical medicineOptical biometryLens Implantation IntraocularGermanyOphthalmologyMyopiamedicineHumansSmall incision lenticule extractionDioptreRetrospective StudiesMathematicsLenses IntraocularPhacoemulsificationmedicine.diseaseSensory SystemsOphthalmology030221 ophthalmology & optometrySurgeryIntraocular lens power calculationRay tracing (graphics)030217 neurology & neurosurgeryJournal of Cataract and Refractive Surgery
researchProduct

Artiflex Toric Phakic Intraocular Lens Implantation in Congenital Nystagmus

2011

Case: A 44-year-old woman with congenital nystagmus and myopic astigmatism in both eyes who was submitted to phakic intraocular lens (pIOL) implantation. Methods: Full ophthalmologic examination including refractive status, corrected (CDVA) and uncorrected (UCVA) monocular and binocular visual acuities, ocular motility, slit-lamp evaluation, tonometry and fundoscopy before and after implantation of toric pIOLs (Artiflex; Ophtec BV, The Netherlands) in both eyes. Results: Preoperative logMAR CDVA were 0.699 and 0.420 in the right and left eye, respectively. Three months after surgery, logMAR UCVA were 0.398 and 0.182, reaching binocular logMAR UCVA of 0.132. There were no changes in nystagmu…

medicine.medical_specialtygenetic structuresbusiness.industrymedicine.medical_treatmentToric phakic intraocular lensNystagmusPhakic intraocular lenseye diseasesMyopic astigmatismOphthalmologyLeft eyeNystagmuslcsh:OphthalmologyOphthalmologic examinationlcsh:RE1-994OphthalmologyRefractive surgeryMedicineIn patientPublished: August 2011sense organsmedicine.symptomRefractive surgerybusinessCongenital nystagmusCase Reports in Ophthalmology
researchProduct